- Journal Home
- Volume 36 - 2024
- Volume 35 - 2024
- Volume 34 - 2023
- Volume 33 - 2023
- Volume 32 - 2022
- Volume 31 - 2022
- Volume 30 - 2021
- Volume 29 - 2021
- Volume 28 - 2020
- Volume 27 - 2020
- Volume 26 - 2019
- Volume 25 - 2019
- Volume 24 - 2018
- Volume 23 - 2018
- Volume 22 - 2017
- Volume 21 - 2017
- Volume 20 - 2016
- Volume 19 - 2016
- Volume 18 - 2015
- Volume 17 - 2015
- Volume 16 - 2014
- Volume 15 - 2014
- Volume 14 - 2013
- Volume 13 - 2013
- Volume 12 - 2012
- Volume 11 - 2012
- Volume 10 - 2011
- Volume 9 - 2011
- Volume 8 - 2010
- Volume 7 - 2010
- Volume 6 - 2009
- Volume 5 - 2009
- Volume 4 - 2008
- Volume 3 - 2008
- Volume 2 - 2007
- Volume 1 - 2006
Commun. Comput. Phys., 13 (2013), pp. 916-928.
Published online: 2013-03
Cited by
- BibTex
- RIS
- TXT
Stent placement is considered as a promising and minimally invasive technique to prevent rupture of aneurysm and favor coagulation mechanism inside the aneurysm. Many scholars study the effect of the stent on blood flow in cerebral aneurysm by numerical simulations, and usually regard blood as the Newtonian fluid, blood, however, is a kind of non-Newtonian fluid in practice. The main purpose of the present paper is to investigate the effect of non-Newtonian behavior on the hemodynamic characteristics of blood flow in stented cerebral aneurysm with lattice Boltzmann method. The Casson model is used to describe the blood non-Newtonian character, which is one of the most popular models in depicting blood fluid. In particular, hemodynamic characteristics derived with Newtonian and non-Newtonian models are studied, and compared in detail. The results show that the non-Newtonian effect gives a great influence on hemodynamic characteristics of blood flow in stented cerebral aneurysm, especially in small necked ones.
}, issn = {1991-7120}, doi = {https://doi.org/10.4208/cicp.281011.020212s}, url = {http://global-sci.org/intro/article_detail/cicp/7258.html} }Stent placement is considered as a promising and minimally invasive technique to prevent rupture of aneurysm and favor coagulation mechanism inside the aneurysm. Many scholars study the effect of the stent on blood flow in cerebral aneurysm by numerical simulations, and usually regard blood as the Newtonian fluid, blood, however, is a kind of non-Newtonian fluid in practice. The main purpose of the present paper is to investigate the effect of non-Newtonian behavior on the hemodynamic characteristics of blood flow in stented cerebral aneurysm with lattice Boltzmann method. The Casson model is used to describe the blood non-Newtonian character, which is one of the most popular models in depicting blood fluid. In particular, hemodynamic characteristics derived with Newtonian and non-Newtonian models are studied, and compared in detail. The results show that the non-Newtonian effect gives a great influence on hemodynamic characteristics of blood flow in stented cerebral aneurysm, especially in small necked ones.