arrow
Volume 13, Issue 3
Non-Newtonian Effect on Hemodynamic Characteristics of Blood Flow in Stented Cerebral Aneurysm

Changsheng Huang, Zhenhua Chai & Baochang Shi

Commun. Comput. Phys., 13 (2013), pp. 916-928.

Published online: 2013-03

Export citation
  • Abstract

Stent placement is considered as a promising and minimally invasive technique to prevent rupture of aneurysm and favor coagulation mechanism inside the aneurysm. Many scholars study the effect of the stent on blood flow in cerebral aneurysm by numerical simulations, and usually regard blood as the Newtonian fluid, blood, however, is a kind of non-Newtonian fluid in practice. The main purpose of the present paper is to investigate the effect of non-Newtonian behavior on the hemodynamic characteristics of blood flow in stented cerebral aneurysm with lattice Boltzmann method. The Casson model is used to describe the blood non-Newtonian character, which is one of the most popular models in depicting blood fluid. In particular, hemodynamic characteristics derived with Newtonian and non-Newtonian models are studied, and compared in detail. The results show that the non-Newtonian effect gives a great influence on hemodynamic characteristics of blood flow in stented cerebral aneurysm, especially in small necked ones.

  • Keywords

  • AMS Subject Headings

  • Copyright

COPYRIGHT: © Global Science Press

  • Email address
  • BibTex
  • RIS
  • TXT
@Article{CiCP-13-916, author = {Changsheng Huang, Zhenhua Chai and Baochang Shi}, title = {Non-Newtonian Effect on Hemodynamic Characteristics of Blood Flow in Stented Cerebral Aneurysm}, journal = {Communications in Computational Physics}, year = {2013}, volume = {13}, number = {3}, pages = {916--928}, abstract = {

Stent placement is considered as a promising and minimally invasive technique to prevent rupture of aneurysm and favor coagulation mechanism inside the aneurysm. Many scholars study the effect of the stent on blood flow in cerebral aneurysm by numerical simulations, and usually regard blood as the Newtonian fluid, blood, however, is a kind of non-Newtonian fluid in practice. The main purpose of the present paper is to investigate the effect of non-Newtonian behavior on the hemodynamic characteristics of blood flow in stented cerebral aneurysm with lattice Boltzmann method. The Casson model is used to describe the blood non-Newtonian character, which is one of the most popular models in depicting blood fluid. In particular, hemodynamic characteristics derived with Newtonian and non-Newtonian models are studied, and compared in detail. The results show that the non-Newtonian effect gives a great influence on hemodynamic characteristics of blood flow in stented cerebral aneurysm, especially in small necked ones.

}, issn = {1991-7120}, doi = {https://doi.org/10.4208/cicp.281011.020212s}, url = {http://global-sci.org/intro/article_detail/cicp/7258.html} }
TY - JOUR T1 - Non-Newtonian Effect on Hemodynamic Characteristics of Blood Flow in Stented Cerebral Aneurysm AU - Changsheng Huang, Zhenhua Chai & Baochang Shi JO - Communications in Computational Physics VL - 3 SP - 916 EP - 928 PY - 2013 DA - 2013/03 SN - 13 DO - http://doi.org/10.4208/cicp.281011.020212s UR - https://global-sci.org/intro/article_detail/cicp/7258.html KW - AB -

Stent placement is considered as a promising and minimally invasive technique to prevent rupture of aneurysm and favor coagulation mechanism inside the aneurysm. Many scholars study the effect of the stent on blood flow in cerebral aneurysm by numerical simulations, and usually regard blood as the Newtonian fluid, blood, however, is a kind of non-Newtonian fluid in practice. The main purpose of the present paper is to investigate the effect of non-Newtonian behavior on the hemodynamic characteristics of blood flow in stented cerebral aneurysm with lattice Boltzmann method. The Casson model is used to describe the blood non-Newtonian character, which is one of the most popular models in depicting blood fluid. In particular, hemodynamic characteristics derived with Newtonian and non-Newtonian models are studied, and compared in detail. The results show that the non-Newtonian effect gives a great influence on hemodynamic characteristics of blood flow in stented cerebral aneurysm, especially in small necked ones.

Changsheng Huang, Zhenhua Chai and Baochang Shi. (2013). Non-Newtonian Effect on Hemodynamic Characteristics of Blood Flow in Stented Cerebral Aneurysm. Communications in Computational Physics. 13 (3). 916-928. doi:10.4208/cicp.281011.020212s
Copy to clipboard
The citation has been copied to your clipboard