- Journal Home
- Volume 36 - 2024
- Volume 35 - 2024
- Volume 34 - 2023
- Volume 33 - 2023
- Volume 32 - 2022
- Volume 31 - 2022
- Volume 30 - 2021
- Volume 29 - 2021
- Volume 28 - 2020
- Volume 27 - 2020
- Volume 26 - 2019
- Volume 25 - 2019
- Volume 24 - 2018
- Volume 23 - 2018
- Volume 22 - 2017
- Volume 21 - 2017
- Volume 20 - 2016
- Volume 19 - 2016
- Volume 18 - 2015
- Volume 17 - 2015
- Volume 16 - 2014
- Volume 15 - 2014
- Volume 14 - 2013
- Volume 13 - 2013
- Volume 12 - 2012
- Volume 11 - 2012
- Volume 10 - 2011
- Volume 9 - 2011
- Volume 8 - 2010
- Volume 7 - 2010
- Volume 6 - 2009
- Volume 5 - 2009
- Volume 4 - 2008
- Volume 3 - 2008
- Volume 2 - 2007
- Volume 1 - 2006
Commun. Comput. Phys., 18 (2015), pp. 1050-1071.
Published online: 2018-04
Cited by
- BibTex
- RIS
- TXT
High intensity focused ultrasound is a rapidly developing technology for the ablation of tumors. Liver cancer is one of the most common malignancies worldwide. Since liver has a large number of blood vessels, blood flow cooling can reduce the necrosed volume and may cause regeneration of the tumor to occur. All cancer cells should be ablated without damaging of the critical tissues. Today, treatment planning tools consider liver as a homogeneous organ. This paper is a step towards the development of surgical planning platform for a non-invasive HIFU tumor ablative therapy in a real liver geometry based on CT/MRI image. This task requires coupling of different physical fields: acoustic, thermal and hydrodynamic. These physical fields can influence each other. In this paper we illustrate how a computational model can be used to improve the treatment efficiency. In large blood vessel both convective cooling and acoustic streaming can change the temperature considerably near blood vessel. The whole tumor ablation took only 30 seconds in the considered simulation case, which is very small comparing with the current treatment time of several hours. Through this study we are convinced that high ultrasound power and nonlinear propagation effects with appropriate treatment planning can sufficiently reduce the treatment time.
}, issn = {1991-7120}, doi = {https://doi.org/10.4208/cicp.171214.200715s}, url = {http://global-sci.org/intro/article_detail/cicp/11060.html} }High intensity focused ultrasound is a rapidly developing technology for the ablation of tumors. Liver cancer is one of the most common malignancies worldwide. Since liver has a large number of blood vessels, blood flow cooling can reduce the necrosed volume and may cause regeneration of the tumor to occur. All cancer cells should be ablated without damaging of the critical tissues. Today, treatment planning tools consider liver as a homogeneous organ. This paper is a step towards the development of surgical planning platform for a non-invasive HIFU tumor ablative therapy in a real liver geometry based on CT/MRI image. This task requires coupling of different physical fields: acoustic, thermal and hydrodynamic. These physical fields can influence each other. In this paper we illustrate how a computational model can be used to improve the treatment efficiency. In large blood vessel both convective cooling and acoustic streaming can change the temperature considerably near blood vessel. The whole tumor ablation took only 30 seconds in the considered simulation case, which is very small comparing with the current treatment time of several hours. Through this study we are convinced that high ultrasound power and nonlinear propagation effects with appropriate treatment planning can sufficiently reduce the treatment time.