arrow
Volume 1, Issue 2
Viscoelastic Models for Passive Arterial Wall Dynamics

D. Valdez-Jasso, H. T. Banks, M. A. Haider, D. Bia, Y. Zocalo, R. L. Armentano & M. S. Olufsen

Adv. Appl. Math. Mech., 1 (2009), pp. 151-165.

Published online: 2009-01

Export citation
  • Abstract

This paper compares two models predicting elastic and viscoelastic properties of large arteries. Models compared include a Kelvin (standard linear) model and an extended 2-term exponential linear viscoelastic model. Models were validated against in-vitro data from the ovine thoracic descending aorta and the carotid artery. Measurements of blood pressure data were used as an input to predict vessel cross-sectional area. Material properties were predicted by estimating a set of model parameters that minimize the difference between computed and measured values of the cross-sectional area. The model comparison was carried out using generalized analysis of variance type statistical tests. For the thoracic descending aorta, results suggest that the extended 2-term exponential model does not improve the ability to predict the observed cross-sectional area data, while for the carotid artery the extended model does statistically provide an improved fit to the data. This is in agreement with the fact that the aorta displays more complex nonlinear viscoelastic dynamics, while the stiffer carotid artery mainly displays simpler linear viscoelastic dynamics.

  • AMS Subject Headings

74D05, 74J25, 62J02, 93A30,92C10, 74L15

  • Copyright

COPYRIGHT: © Global Science Press

  • Email address

htbanks@ncsu.edu (H. T. Banks)

  • BibTex
  • RIS
  • TXT
@Article{AAMM-1-151, author = {Valdez-Jasso , D.Banks , H. T.Haider , M. A.Bia , D.Zocalo , Y.Armentano , R. L. and Olufsen , M. S.}, title = {Viscoelastic Models for Passive Arterial Wall Dynamics}, journal = {Advances in Applied Mathematics and Mechanics}, year = {2009}, volume = {1}, number = {2}, pages = {151--165}, abstract = {

This paper compares two models predicting elastic and viscoelastic properties of large arteries. Models compared include a Kelvin (standard linear) model and an extended 2-term exponential linear viscoelastic model. Models were validated against in-vitro data from the ovine thoracic descending aorta and the carotid artery. Measurements of blood pressure data were used as an input to predict vessel cross-sectional area. Material properties were predicted by estimating a set of model parameters that minimize the difference between computed and measured values of the cross-sectional area. The model comparison was carried out using generalized analysis of variance type statistical tests. For the thoracic descending aorta, results suggest that the extended 2-term exponential model does not improve the ability to predict the observed cross-sectional area data, while for the carotid artery the extended model does statistically provide an improved fit to the data. This is in agreement with the fact that the aorta displays more complex nonlinear viscoelastic dynamics, while the stiffer carotid artery mainly displays simpler linear viscoelastic dynamics.

}, issn = {2075-1354}, doi = {https://doi.org/}, url = {http://global-sci.org/intro/article_detail/aamm/8363.html} }
TY - JOUR T1 - Viscoelastic Models for Passive Arterial Wall Dynamics AU - Valdez-Jasso , D. AU - Banks , H. T. AU - Haider , M. A. AU - Bia , D. AU - Zocalo , Y. AU - Armentano , R. L. AU - Olufsen , M. S. JO - Advances in Applied Mathematics and Mechanics VL - 2 SP - 151 EP - 165 PY - 2009 DA - 2009/01 SN - 1 DO - http://doi.org/ UR - https://global-sci.org/intro/article_detail/aamm/8363.html KW - Arterial wall modeling, dynamic viscoelastic models, inverse problems, statistical analysis for model comparison. AB -

This paper compares two models predicting elastic and viscoelastic properties of large arteries. Models compared include a Kelvin (standard linear) model and an extended 2-term exponential linear viscoelastic model. Models were validated against in-vitro data from the ovine thoracic descending aorta and the carotid artery. Measurements of blood pressure data were used as an input to predict vessel cross-sectional area. Material properties were predicted by estimating a set of model parameters that minimize the difference between computed and measured values of the cross-sectional area. The model comparison was carried out using generalized analysis of variance type statistical tests. For the thoracic descending aorta, results suggest that the extended 2-term exponential model does not improve the ability to predict the observed cross-sectional area data, while for the carotid artery the extended model does statistically provide an improved fit to the data. This is in agreement with the fact that the aorta displays more complex nonlinear viscoelastic dynamics, while the stiffer carotid artery mainly displays simpler linear viscoelastic dynamics.

Valdez-Jasso , D.Banks , H. T.Haider , M. A.Bia , D.Zocalo , Y.Armentano , R. L. and Olufsen , M. S.. (2009). Viscoelastic Models for Passive Arterial Wall Dynamics. Advances in Applied Mathematics and Mechanics. 1 (2). 151-165. doi:
Copy to clipboard
The citation has been copied to your clipboard