abstract = {The basic theory of camera calibration is firstly introduced in this paper. The model of camera distortion
is put forward. And discussed the parameters and the calibration process of the mathematical model of
3D human body reconstruction. In the process of camera calibration, an improved algorithm based on
the two steps is proposed. This method has low requirements on experimental. This method has low
requirement to experiment, and only with coplanar points to calibrate. By the process of fractional step
calibration, the nonlinear equation is linear, which is beneficial to improve the calibration accuracy.},
issn = {2617-8699},
doi = {https://doi.org/10.3993/jfbim00161},
url = {http://global-sci.org/intro/article_detail/jfbi/4748.html}
}
TY - JOUR
T1 - Non-contact Human Body Measuring Technology Based on Camera Calibration Technique
AU - Yue Wang & Shoushan Jiang
JO - Journal of Fiber Bioengineering and Informatics
VL - 4
SP - 667
EP - 677
PY - 2015
DA - 2015/08
SN - 8
DO - http://doi.org/10.3993/jfbim00161
UR - https://global-sci.org/intro/article_detail/jfbi/4748.html
KW - Non-contact Human Body Measurement
KW - Camera Calibration
KW - The Radial Distortion
KW - Non-linear Model
AB - The basic theory of camera calibration is firstly introduced in this paper. The model of camera distortion
is put forward. And discussed the parameters and the calibration process of the mathematical model of
3D human body reconstruction. In the process of camera calibration, an improved algorithm based on
the two steps is proposed. This method has low requirements on experimental. This method has low
requirement to experiment, and only with coplanar points to calibrate. By the process of fractional step
calibration, the nonlinear equation is linear, which is beneficial to improve the calibration accuracy.