TY - JOUR T1 - Fabrication and Voltammetric Characters of Carbon Paste Electrode Modified Using Poly-Silk Peptide AU - Mingming Ma, Qiang Zhao & Zhi Tong JO - Journal of Fiber Bioengineering and Informatics VL - 3 SP - 277 EP - 283 PY - 2013 DA - 2013/06 SN - 6 DO - http://doi.org/10.3993/jfbi09201305 UR - https://global-sci.org/intro/article_detail/jfbi/4841.html KW - Silk Peptide KW - Electropolymerization KW - Carbon Paste Electrode AB - A new material poly-silk peptide was fabricated using the electropolymerization of Silk Peptide (SP) on the surface of a Carbon Paste Electrode (CPE) for the first time. The morphological feature of poly-silk peptide film was characterized by Scanning Electron Microscopy (SEM). The preparation conditions such as SP concentration, supporting electrolyte pH and scan cycles were optimized. A stable poly- silk peptide film could be obtained with scanning 16 cycles in pH7.4 Phosphate Buffer Solution (PBS) containing 0.6 g⋅L^{-1} SP between -0.5 and +1.5V. In addition, a well-defined pair of oxidative and reductive peaks of poly-silk peptide was observed in 0.1M H_2SO_4 solution (pH 1.1), resulting from the successive redox reaction of -OH, -C=O and -COOH groups on poly-silk peptide.